 DIP 1 and 2 definition:

Table 2.41

DIP Switch

Off

On

1

Ring is deactivated

Ring is activate

2

Slave

Master

 DIP 3 and 4 definition:

Table 2.42

DIP Switch 3

DIP Switch 4

Ring Type

Off

Off

Select ERPS

Off

On

Select iA-Ring

On

Off

Select Compatible-Ring (only slave mode is
supported)

 Factory default setting:

o DIP Switch 1: OFF (Ring is inactive)

o DIP Switch 2: OFF (Slave is selected)

o DIP Switch 3/4: OFF/OFF (ERPS is selected)

DIP switch 1 must be set to the “ON” position to enable DIP switches 2, 3, and 4. If

DIP switch 1 is set to the “OFF” position, then DIP switches 2, 3, and 4 will all be

disabled.

When DIP 1 is set to “ON”, the default ring ports are Port9 and Port10 (Port10 is

RPL port).

 When the Compatible-Ring is selected, DIP 2 is unused.

For example, if users want to set this device to be a master in an ERPS Ring, DIP switch 1

and 2 should be on, and DIP switch 3 and 4 should be off. These settings define the device

to be a master with Port10 being RPL in an ERPS ring.