4.6.2 COM Configuration

Figure 4.18

Configure serial settings in this page, Figure 4.18. Note that these settings need to match the

ones in the serial device.

Serial Interface: Select between RS-232, RS-422, and RS-485. Note that RS-485 refers to

2-Wire RS-485 and RS-422 is compatible with 4-Wire RS-485.

Baud Rate: Select one of the baudrates from the dropdown box.

Parity / Data Bits / Stop Bits: Configure them accordingly.

Flow Control: Choose between No Flow Control, RTS/CTS (Hardware Flow Control), and

Xon/Xoff (Software Flow Control). If Xon/Xoff is selected, Xon and Xoff

characters are changeable. Defaults are 0x11 for Xon and 0x13 for Xoff. If the

connecting program or serial device would like to receive the Xon/Xoff signals

also, enable

“Permit Xon/Xoff Character Pass Through”