3 com configuration: advanced settings, Com configuration: advanced settings – Atop Technology SW550XC User manual User Manual

Page 40

Advertising
background image


Industrial Wireless Serial Device Server Series
SW550xC User Manual V 1.0

35

4.6.3 COM Configuration: Advanced Settings

Figure 4.19

TCP

TCP Timeout:

Specify the value in “TCP Timeout” to force SW550xC actively close a

TCP connection after some specific inactivity time (no packets). The default value for it is

3600 seconds. Disabling this option means SW550xC would never actively close an

established connection.

Delimiters

Serial to Network Packet Delimiter: Packet delimiter is a way of packing data in the

serial communication. It is designed to keep packets in track. SW550xC provides three

types of delimiter: Time Delimiter, Maximum Bytes and Character Delimiter. Note that the

following delimiters (Interval, Max Byte and Character) are programmed in the OR logic.

Meaning that if any of the three conditions were met, SW550xC would transmit the serial

data in its buffer over the network.

Advertising