Tcp server application: multi-point tcp pair, Connections – Atop Technology SW550XC User manual User Manual

Page 75

Advertising
background image


Industrial Wireless Serial Device Server Series
SW550xC User Manual V 1.0

70

5.2.10

TCP Server Application: Multi-Point TCP Pair

Connections

The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection

is that the TCP implementation would also exchange flow control pins for RS-232. However,

the TCP Server is limited to a maximum of four connections. If there are four serial devices and

they don’t use flow control pins with RS-232 or RS-485, it is possible to setup pair connection

in UDP mode,

Sec. 5.2.8

.After multi-connection is enabled in the WebUI, refer to the following

table to setup Pair Connection as in Figure 5.18

Table 5.2

IP Address

Link Mode

Application

Local Listening

Port

Destinatio

IP

Destination

Port

SW5501C

Master

COM1

10.0.50.100

TCP Server

Pair Connection

Master

4660

-

-

SW5502C

Slave 1

COM1

10.0.50.200

TCP Client

Pair Connection

Slave

-

10.0.50.100

4660

SW5502C

Slave 1

COM2

10.0.50.200

TCP Client

Pair Connection

Slave

-

10.0.50.100

4660

SW5501C

Slave 2

COM1

10.0.50.201

TCP Client

Pair Connection

Slave

-

10.0.50.100

4660

SW5501C

Slave 3

COM1

10.0.50.202

TCP Client

Pair Connection

Slave

-

10.0.50.100

4660

Advertising