L1 l2 l3 grd, Electrical connections – CHAMPION 54 DR Series-90DRHDPW Manual User Manual
Page 14

6
1. Motor rotation was set at the factory.
2. The conveyor drive motor rotation is indicated by a red arrow located on the side of
the motor.
3. Check if all motors are running in the wrong direction. Reverse the L1 and L2 wires on
the output side of the dishwasher Main Terminal Block (MTB) located inside the top-
mounted control cabinet.
4. The photograph to the right shows the conveyor drive motor with its direction arrow.
5. A wash pump/motor assembly can be seen in the back.
Installation
Electrical Connections
(continued)
Motor Rotation
THREE PHASE
POWER CONNECTION
LINE IN
L1
L2
L3
GRD
Main Terminal Block Inside the Top-mounted Control
Cabinet.
Motor Direction Rotation Label on Motor Frame.
WARNING:
Moving Conveyor Parts may cause INJURY OR DEATH.
Keep hands and clothing clear of the conveyor when the
conveyor is moving.
USE EXTREME CAUTION WHEN THE CONVEYOR
IS MOVING.