CHAMPION 54 DR Series-90DRHDPW Manual User Manual

Page 168

Advertising
background image

160

1.
Power and Pause LEDs are on

2.
Drive Jam Switch is closed (NC) LED is on.

3.
Table Limit Switch is closed (NC) LED is on.

4.
Final Rinse Trip Switch is closed (NC) LED is on.


(no dish rack is present

)

5.
Rack Trip Switch is closed (NC) LED is on.


(no dish rack is present)


The rack switch starts the pumps and drive.

6.
LEDs for the lower and upper floats in each tank


are labeled on the board as follows:


Wash Flt U = wash tank upper float


Wash Flt L = wash tank lower float


Prewash Flt U = prewash tank upper float


Prewash Flt L = prewash tank lower float


DR Level Rinse Flt U = DR tank single float


on single tank machine or the Rinse tank lower


float on two tank machines.


Rinse Flt U = rinse tank upper float on two tank


machines.

7.
As the machine starts to fill the lower floats will


rise closing the lower float switch. The lower float


LED comes on for each tank as it fills.

8.
When the lower float switches close the Heat LEDs


will come on and the respective heat circuit outputs are enabled.


The booster and wash heat contactors pull in if the thermostats call for heat.


The DR heater contactor on a single tank DR machine will pull in if the thermostats call for heat.


If the machine is a two tank machine then the rinse tank theater contactors pull in if the thermostats call for heat

.


NOTE: The DR and Rinse Heat shares the same LED because the two tank machine never has a DR tank.

Current State 1 (continue

d):

Dishwasher power switch is on.

Machine continues to fill.

W

ash Heat LED on when

wash tank lower

float is satisfied

DR/Rinse Heat LED is on when DR tank

float is satisfied or

, if a two tank machine,

when rinse tank lower float is satisfied

.

LED of

f when

the tank is full.

Booster Heat LED

is on whenever

wash heat LED is on

Advertising