Condition

Cause

Solution

Dishwasher will not run.

Low or no water.

Door not closed.

Main power OFF.

Dishwasher OFF.

Wash tanks not full

Main water supply off.

PRV setting incorrect or low

incoming pressure.

Solenoid strainer clogged.

Solenoid valve defective.

Defective float switch.

Close door completely.

Check breaker on panel.

Turn dishwasher ON.

Check drain valves.

Open supply valve.

Adjust the PRV to 22psi

flowing pressure.

Clean strainer.

Contact Service Agent.

Contact Service Agent.

Dishwasher stays in

wash cycle.

Conveyor jammed or table

limit switch has stopped

conveyor.

Green start button not

pressed.

Machine filled for 20

minutes but did not reach

fill level and shut down.

Contact Service Agent.

Contact Service Agent.

Poor wash results.

Detergent not added to tank.

Wares incorrectly loaded.

in dishrack.

Clogged screens .

Clogged spray arms.

Thermostat defective.

End plugs missing.

Water temperature low.

Check detergent suppy.

Reposition wares or reduce

amount of wares.

Clean screens.

Clean spray arms.

Contact Service Agent.

Check spray arms.

Check incoming water

temperature.

Dishwasher conveyor

will not run.

Idle pump switch defective.

90 second timer defective

Check conveyor for jams

Remove racks from load

end of table.

Press Green start button &

insert rack into machine.

Check drain valves, turn

power ON and OFF, then

push Green Start button.

Incoming water temperature

low.

Defective heater.

Defective temperature

display.

Low tank and/or final

rinse temperature.

Check incoming tempera-

ture/contact maintenance.

Contact service agent.

Contact service agent.

Before calling for service check the following conditions.
1. Dishwasher main power and water supply is on.
2. Machine has been assembled correctly.
3. Conveyor is clear of any obstructions.
4. Drains are closed.
5. Screens and pump intake screens are clear.
6. Doors are closed and secure.