22

CAUTION:

De-liming agents can cause chemical burns. Wear rubber gloves, eye protec-

tion and any other protective clothing as instructed by a qualified chemical

supplier and follow the instructions provided by the chemical supplier.

WARNING:

Death or injury can result from toxic fumes when de-liming agents come in

contact with Chlorine Bleach, or other chemicals that contain iodine, bromine,

or fluorine.

UsE EXTREmE CAUTION WHEN HANDlING ANY DE-lImING AGENT

Cleaning

Cleaning

(continued)

At the End of the Day

1. Perform Steps 1-10 on the previous page.
2. Remove the upper and lower rinse and wash spray arms and end plugs and flush with fresh

water.
3. Remove the Dual Rinse (DR) rinse arm assemblies and flush with fresh water.
4. Clean the final rinse arm nozzles using a small paper clip.
5. Remove the curtains and clean with fresh water.

DO NOT UsE sTEEl WOOl TO ClEAN THE INTERIOR OF THE mACHINE.

6. Wipe the interior and exterior of the machine with a soft cloth and a mild detergent.

DO NOT HOsE THE EXTERIOR OF THE mACHINE WITH WATER.

7. Reassemble the dishwasher and leave the door open to allow overnight drying
8. Contact the chemical supplier for de-liming if required.

De-liming

Lime (scale) deposits are the result of minerals contained in the water feeding the dishwasher

and appear as a white haze on the surface of the dishwasher. Severe scaling can appear as a

granular deposit. These deposits are a result of the mineral content in the geographic area of the

machine's location.

ATTENTION:

Place a flat-bottom dish rack upside down on the idle pump start switch at the

entrance end f the dishwasher to keep the dishwasher running during the

de-liming procedure.