Chemical connections, Vent fan signal connection – CHAMPION 54 DR Series-90DRHDPW Manual User Manual
Page 15

7
1. Use a qualified detergent/chemical supplier
for detergent/chemical and dispensing
equipment needs.
2. Labeled detergent control circuit connection
terminals are provided in the control cabinet
for detergent and rinse agent/sanitizer
dispensing equipment (supplied by others).
3. The illustration on the right, shows the
terminal board for the machine.
4. The signal connection points include:
• Detergent signal 120VAC, 1A max load.
• Rinse aid/Sanitizer signal 120VAC, 1A load.
• Vent Fan 120VAC, 1Amp max amp load
5. A removable black plug is provided in the
load end side of the wash tank for installation
of the detergent conductivity cell.
SIGNAL ONLY
VENT FAN
COMMON
COMMON
120V
DETERGENT
120V
RINSE AID
120V
Installation
Chemical Connections
MACHINE
RUNNING
TABLE
LIMIT
SWITCH
SIGNAL ONLY
1. Connections are provided for systems that
require that a signal to indicate the dishwasher
is running.
2. A signal connection is provided to indicate
that the dishwasher has stopped due to a
conveyor jam or when the clean dish table
is full of racks and additional racks cannot
exit the machine.
3. The table limit switch option is recommended
be installed on all dishwashers and can be
ordered from the factory P/N 407400.
Machine Running & Table Limit Switch Signal Connections
1. A terminal block is provided inside the top-mounted control
cabinet to provide a 120VAC, 1 AMP Max Load signal.
NOTE:
The Vent Fan Signal Connection supplies 120VAC to a control
relay (supplied by others) when the dishwasher is ON and O
VAC when the dishwasher is OFF. Power to operate the vent
fan (supplied by others) must be supplied separately.
Vent Fan Signal Connection
SIGNAL ONLY
VENT FAN
COMMON
COMMON
120V
DETERGENT
120V
RINSE AID
120V
Detergent
Probe Location