1. Use a qualified detergent/chemical supplier

for detergent/chemical and dispensing

equipment needs.

2. Labeled detergent control circuit connection

terminals are provided in the control cabinet

for detergent and rinse agent/sanitizer

dispensing equipment (supplied by others).

3. The illustration on the right, shows the

terminal board for the machine.

4. The signal connection points include:

• Detergent signal 120VAC, 1A max load.

• Rinse aid/Sanitizer signal 120VAC, 1A load.

• Vent Fan 120VAC, 1Amp max amp load

5. A removable black plug is provided in the

load end side of the wash tank for installation

of the detergent conductivity cell.

SIGNAL ONLY

VENT FAN

COMMON

COMMON

120V

DETERGENT

120V

RINSE AID

120V

Installation

Chemical Connections

MACHINE
RUNNING

TABLE
LIMIT
SWITCH

SIGNAL ONLY

1. Connections are provided for systems that

require that a signal to indicate the dishwasher

is running.

2. A signal connection is provided to indicate

that the dishwasher has stopped due to a

conveyor jam or when the clean dish table

is full of racks and additional racks cannot

exit the machine.

3. The table limit switch option is recommended

be installed on all dishwashers and can be

ordered from the factory P/N 407400.

Machine Running & Table Limit Switch Signal Connections

1. A terminal block is provided inside the top-mounted control

cabinet to provide a 120VAC, 1 AMP Max Load signal.

NOTE:

The Vent Fan Signal Connection supplies 120VAC to a control

relay (supplied by others) when the dishwasher is ON and O

VAC when the dishwasher is OFF. Power to operate the vent

fan (supplied by others) must be supplied separately.

Vent Fan Signal Connection

SIGNAL ONLY

VENT FAN

COMMON

COMMON

120V

DETERGENT

120V

RINSE AID

120V

Detergent

Probe Location