1

UI Overview and Installation

16

System Status

When the Echo ACP is installed and power is applied to the enclosure, the graphic LCD

illuminates and displays Dimming Rack Status.

Check the status LEDs for indication of power, control, and rack status. Each indicator is

visible from the front panel of the Echo ACP with the DRd enclosure door closed.

The following indicators are featured:

Power LED - indicates on solid when the controller has power

DMX input status - slow blink when no DMX input is received, fast blink when there is
a data error, on solid when valid DMX input is received.

Ethernet status - blinks with Ethernet network activity

Error status - slow blink when errors or warning are present and is off when there no
errors present. The Error LED is accompanied by status messages on the graphic LCD.

See “View/Clear Errors Menu” on page 56.

Dimming Rack Status

System OK

DMX Start = 155

Ш1: 119

Ш2: 119

Ш3: 120

60Hz 102F

v5.6.7

Arch Control Status

Preset 15 Active

Sequence Inactive

System OK

DMX Start = 155

DMX Input: Active

DRd12

v1.2.3

Clockwise rotation on the touch
wheel changes the status display
to Arch Control Status.

Counter-clockwise rotation on the
touch wheel changes the status
display back to Dimming Rack
Status.