Menu flow chart, 79 echo acp configuration manual – ETC Echo Architectural Control Processor (ACP) v1.0.0 User Manual

Page 84

Advertising
background image

79

Echo ACP Configuration Manual

Menu Flow Chart

Note:

Note:

Space 1:

2

Space 2:

1, 16

Space 5:

5-7, 16

Space 6:

5-7, 16

Space 7:

5-7, 16

Space 8:

None

Space 16:

2, 5-7

About

1 About Dimmer
2 Level Summary
3 Version Info

4 Space Combine

Version Info

Space Combine

Echo ACP App:
1.0.0.0.0.0.05
DRd: 1.3.0.9.0.61
FLO: 1.0.1.9.0.22
Echo Protocol:

1.0.0.0.0.123

Echo PHY:
1.1.1.0.1211

When the rack is

a DRd12-48, two racks

display in the list with
appended number 1 or 2.

FLO or DALI version info

displays only when they

are installed.

Shows each dimmer

position of rack, along

with Circuit number, winning

control source, and its

current level.

1 About Dimmer
2 Level Summary

3 Version Info

4 Space Combine

About

Current Level:

100%

DMX Level:

45%

sACN :evel:

0%

Arch Level:

33%

Set Level:

0%

Panic/Emer: 100%

About Dimmer

1

< p u s h E n t e r f o r m o r e >

About Dimmer

1

DMX address:

125

sACN address:

1234/123

Module Type:

D20F

Mode: Fluorescent
Space: Space

1

Current Level:

100%

<push Enter for more>

1 About Dimmer

2 Levels Summary
3 Version Info
4 Space Combine

About

Dim Ckt Src Level
1 1 DMX

255

2 24

sACN

128

3 3 Arch

75

4 4 ---

---

5 5 DMX

255

6 6 Emerg

255

7 7 Set

0

1 About Dimmer

2 Level Summary

3 Version Info
4 Space Combine

About

Arch Setup

Remote Record

Off

Data Source Settings

Data Loss & Power On
Preferences
Space Setup
Network Settings

Data Source Settings

DMX Input:

Enabled

DMX Priority:

100

Arch Priority:

100

Arch Setup

Remote Record

Off

Data Source Settings

Data Loss & Power On

Preferences
Space Setup
Network Settings

Data Loss Behavior

Mode:

Hold Last Look

Wait Time:

Forever

sACN Loss Behavior
Mode:

Wait and Fade

Wait Time:

3 min 0 sec

Fade Time:

0 min 3 sec

Power On Behavior
Mode: None

Note:

Note:

Specify a

range of dimmers for

dimmer setup. When a range

of dimmers is selected, those

properties that are not equal

display as blank. Edits made to empty

properties apply to all applicable.

The available module type list is

rack voltage dependent. Changing

a module type defaults all

properties for the specified

dimmer(s).

Each

dimmer must have a

Space assignment. By default

this is set to Space 1. The

available Spaces are defined in

the Arch Setup > Space Setup menu.

A maximum of 8 spaces are allowed.

Specify a Zone and Circuit assignment

for each dimmer. Zones are assigned by

default to the first 16 consecutive

dimmers in the same space.

Circuit numbers by default

match the dimmer number.

Module Type:

D20

Mode:

Normal

Curve:

Mod Square

Threshold:

1 %

Voltage Reg:

On

Max Scale:

118 V

Min Scale:

6 V

Dyn Preheat:

Off

Transformer mode:

On

DMX Res:

Hi 16 bit

Space:

1

Zone:

1

Circuit:

1

Name: Circuit

1

Dimmer Setup

Dimming Setup

Dimmer Setup

Patch DMX Input
Patch sACN Input
Emergency Setup
Quick Rack Setup

Push to Set Levels

1

Note:

Specify a

range of dimmers.

Dimmer doubled dimmers

are applied a default +256

offset. Hi and lo resolution
dimmers default a +1 offset.

Uneditable dimmers

display as NA.

Patch DMX Input

1:

111 a

111 b

2: 112

a

368

b

3: NA
4: 113
5: 114

H

115

L

6: 116

a

117

b

Dim DMX

Dimming Setup

Dimmer Setup

Patch DMX Input

Patch sACN Input
Emergency Setup
Quick Rack Setup
Push to Set Levels

Note:

Patch Dimmers

DIM

sACN

Univ

1:

111 a

111 b

63999

2: 112

a

368

b 1

3: NA
4: 113

1

5: 114

H

115

L 1

6: 116

a

117

b 2

Specify a

range of dimmers. Edit

sACN patch data and specify

universe configuration.

Up to four sACN input

universes can be configured

to the dimmers.

Dimming Setup

Dimmer Setup
Patch DMX Input

Patch sACN Input

Emergency Setup
Quick Rack Setup
Push to Set Levels

Note:

Emergency Dimmers

1:

O n

2: O n

3: --

4: O n

5: --

6: --

7: O n

8: O n

9: O n

1 0: --

11: O n

1 2: O n

13: N A

1 4: N A 1 5 A : O n

1 5 B:O n 1 6 A :O n 1 6 B:

O n

On is default,

-- =off, NA =dimmer that

is not applicable such as a

CC20 or single density dimmer.

Dimmer doubled dimmers have

“a”&“b” dimmers. Use [and]

and [thru] functions

to select.

Emergency Dimmers

Emergency Level:

100

Load Shedding:

On

Input Type:

Maintained

Active When:

Closed

Emergency Setup

Dimming Setup

Dimmer Setup
Patch DMX Input
Patch sACN Input

Emergency Setup

Quick Rack Setup
Push to Set Levels

Note:

Module

types vary by

operating voltage. Changing

the module type defaults all

dimmer properties.

Apply changed settings* only

or all settings using the

menu options.

Dimmer Setup
Patch DMX Input
Patch sACN Input
Emergency Setup

Quick Rack Setup

Push to Set Levels

Dimming Setup

Voltage L-N:

Auto

Rack Type:

Auto

Module Type:

D20

Balance: Straight
DMX Start Addr:

1

sACN Universe:

1

sACN Start Addr:

1

Space: 1
Temp: Auto

Apply Changes * Only

Apply All

Quick Rack Setup

Dimming Rack Status

System OK

DMX Start = 1

Ш1: 119

Ш2: 119

Ш3: 120

60Hz 102F v1.0.2

Arch Control Status

No Active Preset

IP: 10.101.166.101

System OK

DMX Start = 312

DMX Input: Active

DRd12

v1.2.3

A
A

A

A
A

A

A
A

A

Main Menu

1 About

2 Dimming Setup
3 Arch Setup
4 Dimming Control
5 Arch Control
6 File Operations
7 View/Clear Errors
8 Restricted Access

D

1 About
2 Dimming Setup

3 Arch Setup

4 Dimming Control
5 Arch Control
6 File Operations
7 View/Clear Errors
8 Restricted Access

1 About

2 Dimming Setup

3 Arch Setup
4 Dimming Control
5 Arch Control
6 File Operations
7 View/Clear Errors
8 Restricted Access

Main Menu

Main Menu

Advertising