Module type, Balance, Dmx start address – ETC Echo Architectural Control Processor (ACP) v1.0.0 User Manual

Page 40: N o t e

Advertising
background image

35

Echo ACP Configuration Manual

Module Type

Module type allows you to quickly set all dimmers in the DRd rack to a single type. Available

modules are determined by the voltage which is automatically determined at power up.

Reference

Dimmer Specifications, page 62

for dimmer module property defaults.

For a 100-130 V AC dimmer rack, the default is a D20 dimmer module.

For a 230-240V AC dimmer rack, the default is an ED15 dimmer module.

For a 277V AC dimmer rack, the default is an AD20 dimmer module.

Step 1:

Use the touch wheel to scroll to “Module Type”, press enter (

). The module

type menu list displays for selection.

Step 2:

Use the touch wheel to scroll the module type list, press enter (

) to make your

selection.

Step 3:

Use the touch wheel to scroll to the next setup option or scroll to “Apply Changes
Only” or “Apply All”. Press enter (

) to select.

Balance

This setting is automatically defaulted to “Straight”. Other settings include “3 Phase Bal” or

“1 Phase Bal”.

Step 1:

Use the touch wheel to scroll to “Balance”, press enter (

) repeatedly to cycle

through the available options.

Step 2:

When the desired value is displayed, use the touch wheel to scroll to the next
setup option or scroll to “Apply Changes Only” or “Apply All”. Press enter (

) to

select.

DMX Start Address

This setting is automatically defaulted to “1”. The start address corresponds to the first

address you wish to patch DRd dimmers in the enclosure. When using the “DMX Start

Addr” setting, addresses may range from 1 to 501 depending on the type of dimmer rack.

The highest DMX address for any dimmer allowed is 512.

A universe of DMX is a group of 512 contiguous control channels. When using the “DMX

Start Address” menu feature, addresses may start at one or any number up to 512 minus

the number of dimmers in the enclosure, depending on the type of enclosure(s) you are

programming.

Step 1:

Use the touch wheel to scroll to “DMX Start Addr” and press enter (

) to select.

Step 2:

Use the touch wheel to scroll or use the numeric button pad to specify a start
address. Press enter (

) to select.

Step 3:

Use the touch wheel to scroll to the next setup option or scroll to “Apply Changes
Only” or “Apply All”. Press enter (

) to select.

N o t e :

Un-editable dimmers, such as the CC20 module, are not assigned addresses in

this operation.

Dimmer doubled dimmers are, by default, applied a default +256 address offset.

When this results in an address greater than 512, the address for the “B” side of

the dimmer is set to equal the “A” side of the dimmer.

High resolution dimmers are applied a default +1 address offset.

N o t e :

If the selected start address doesn’t allow for unique addresses for each dimmer

in the enclosure (for example a DRd6 with a start address of 506), the dimmers

outside of the allowable range of 512 will remain un-patched.

Advertising