Profibus dp, 1 dp telegrams, 1 diagnostics – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual

Page 119: Dp telegrams, Diagnostics

Advertising
background image

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

PROFIBUS DP

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

119

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

11.

PROFIBUS DP

This chapter contains all necessary information to operate the AS-i/PROFIBUS
gateways as part of a PROFIBUS DP network.

11.1

DP telegrams

11.1.1

Diagnostics

The following blocks may be optionally appended to the DP diagnostics. Bytes
1 … 4 are sent in each block according to the PROFIBUS standard.

Only when double masters are used is the entry „circuit 2“ available in the AS-i
flags, delta list and LPF.

DP diagnostics

Byte

description

1

station state 1

2

station state 2

3

station state 3

4

Master address

5

ident high

6

ident low

Tab. 11-4.

AS-i flags

Byte

description

1

0x06 header

2

0xA0 (circuit 1)/0xA1 (circuit 2) type

3

0x00 slot

4

0x00 spec

5

EC flags (high)

6

EC flags (low)

Tab. 11-5.

Delta list

Byte

description

1

0x0C header

2

0xA2 (circuit 1)/0xA3 (circuit 2) type

3

0x00 slot

4

0x00 spec

5

delta (0 … 7)

Tab. 11-6.