Appendix: example of a bidirectional safety coupling
Subject to reasonable modifications due to technical advances
Id.-No.: 103329
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
173
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
Couple slaves:
A =
Couple slave circuit 1, OSSD 1, Address 1
B =
Couple slave circuit 2, OSSD 1, Address 1 (contains all EMER-
GENCY STOPs)
Configuration:
1.
The couple slaves on the monitor are to be configurated
first! (AS-i Safety>Safety Coupling).
2.
Deactivate the "Coupling AS-i 1" first
3.
Configure the monitor from the circuit 2
4.
Configure the monitor from the circuit 1
5.
Activate the "Coupling AS-i 1" on the monitor from the
circuit 2.