3 profibus (main menu), 1 profibus adresse (profibus station address), 2 profibus status – EUCHNER AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor for 2 AS-i circuits User Manual

Page 69: Profibus (main menu), Profibus adresse (profibus station address), Profibus status, Profibus address profibus status

Advertising
background image

AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor

Operation in advanced display mod

Subject to reasonable modifications due to technical advances

Id.-No.: 103329

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

69

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

9.3

PROFIBUS (main menu)

Main menu || PROFIBUS ||

This menu enables PROFIBUS configuration and diagnostics.

9.3.1

PROFIBUS ADRESSE (PROFIBUS Station Address)

Main menu || PROFIBUS || PROFIBUS ADDRESS ||

This function is used to set and change the PROFIBUS station address.

The number following "Old Address" shows the current station address. By se-
lecting "New Address", the address can be changed.

9.3.2

PROFIBUS STATUS

Main menu || PROFIBUS || PROFIBUS STATUS ||

The function PROFIBUS Status indicates if and how many connections are active
on each PROFIBUS channel.

PROFIBUS ADDRESS
PROFIBUS STATUS

PROFIBUS ADDRESS: setting of the PROFIBUS station address.

PROFIBUS STATUS: status of PROFIBUS connections.

PROFIBUS ADDRESS
OLD ADDRESS

099

NEW ADDRESS

003

PROFIBUS ADDRESS
PROFIBUS STATUS

PROFIBUS STATUS
DPV0: 1 CONN
DPV1: 0 CONN

DP/V0: number of active cyclic connections.

DP/V1: number of active acyclic connections.