Installation

RTCSmp Built-In Module-Line Griddle & Braising Pan


Part # 4532414 Rev 2 (1/15/14)

13

4.5.2 Operation Unit (Griddle and Braising Pan)

NOTE

The operation unit is to be stud-mounted VERTICALLY onto the back of the panel.
Installers are responsible for choosing the appropriate fasteners for the installation.

IMPORTANT Clearance behind the operation unit: min 55mm / 2.16”.

4.5.2.1 Dimensions of Operation Unit, RTCSmp Module-Line Dual Griddle and Braising Pan

(Measurements in mm and [inch])

4.5.2.2 Template and Installation Steps

1. Use the dimensions below as a guide, install studs and create the cut-outs on the panel.

2. The plastic knobs are pressure fitted to the switches.

Remove the knobs. Fasten (fasteners not provided) the
unit to the back of the panel; use the four holes on the
housing and stud mount the unit.

3. Use four M4 screws (two for each rotary switch) to attach

the switches to the panel. This prevents the switches
from rotating.

4. Apply overlay (provided, P/N 66000071) to the panel

and install knobs. dimension of the overlay:
638.5mm x 76.6mm (25.1”x 3.0”).