4 electrical specifications, 5 operating conditions, 6 compliances – Garland MODUKB10000150 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN User Manual

Page 9

Advertising
background image

Dimensions and Technical Specifications

RTCSmp Built-In Module-Line Griddle & Braising Pan


Part # 4532414 Rev 2 (1/15/14)

9

3.4 Electrical Specifications

Model

Voltage

Power

Conductor Size #Cook Zones

MODUGR 7000

208 V AC / 3Ph / 60Hz

7000W (2x3500 W) / 22A

AWG 10

2

400 V AC / 3Ph / 50Hz

7000W (2x3500 W) / 11A

1.5mm

2

440 V AC / 3Ph / 50Hz

7000W (2x3500 W) / 10A

1.5mm

2

MODUGR 10000

208 V AC / 3Ph / 60Hz

10000W (2x5000 W) / 30A

AWG 8

2

400 V AC / 3Ph / 50Hz

10000W (2x5000 W) / 16A

2.5mm

2

440 V AC / 3Ph / 50Hz

10000W (2x5000 W) / 15A

2.5mm

2

MODUKB 7000

208 V AC / 3Ph / 60Hz

7000W (2x3500 W) / 22A

AWG 10

2

400 V AC / 3Ph / 50Hz

7000W (2x3500 W) / 11A

1.5mm

2

440 V AC / 3Ph / 50Hz

7000W (2x3500 W) / 10A

1.5mm

2

MODUKB 10000

208 V AC / 3Ph / 60Hz

10000W (2x5000 W) / 30A

AWG 8

2

400 V AC / 3Ph / 50Hz

10000W (2x5000 W) / 16A

2.5mm

2

440 V AC / 3Ph / 50Hz

10000W (2x5000 W) / 15A

2.5mm

2

3.5 Operating Conditions

Max. Tolerance of Nominal Supply Voltage

+6 /-10 %

Network Impedance (Zmax.)

0.25Ω

Supply frequency

50/60 Hz

Amperage Nominal Value: 400V, 3Ph

10A for the 7kW built-in generator (4x 1.5mm

2

)

15A for the 10kW built-in generator (4x 2.5mm

2

)

Amperage Nominal Value: 208V, 3Ph

20A for the 7kW integrated generator (4x AWG 10)
29A for the 10kW integrated generator (4x AWG 8)

Ingress Protection class

IP X0

Maximum Ambient Temperature

In Storage > -4°F to +158°F (-20°C to +70°C)
In Operation >+ 41°F to +104°F (+5°C to +40°C)

Maximum Relative Air Humidity

In Storage > 10% to 90%
In Operation > 30% to 90%

Set Temperature Range

95 - 450

o

F (35 - 230

o

C)

Temperature Regulator

Potentiometer 10 kOhm

Clearance from materials

Min. 1.57”(40mm) for air intake and exhaust openings
Min. 0.39”(10mm) for side clearance

Maximum fan air flow: 70.63 cfm (120 m

3

per hour). Minimal opening of 10.08 sq. in. (6500 mm

2

) is required

around the fan.

3.6 Compliances

North American models:

ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001

CE models

comply with the latest European Norms:

EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)

Advertising