4.6 Electrical Installation
IMPORTANT
• Refer to the electrical specifications in chapter 3 Dimensions and Technical Specifications AND the
rating plate/instruction labels on the unit. Always refer to the rating plate/instruction labels on the
unit to verify the electrical data. The rating plate/label information overrides the information listed in this
manual.
• Check and ensure the supply voltage and the line current match the specifications given on the rating
plate. A stable mains supply must be provided.
CAUTION
Wrong voltage will damage the induction unit. Follow
strictly the specifications on the rating plate.
• The electrical connections must satisfy the national and local electrical codes.
• If using a Circuit Breaker (Fault circuit Interrupter—FI switch), when switching a generator to a three-
phase mains supply, make sure that it can temporarily dissipate generated power, caused by the
asymmetry, which could result in activation of a Circuit Breaker (FI switch).
When selecting the Circuit Breaker (FI switch), make sure a frequency range of approx. 20kHz can be
generated by the generator DC and AC. We recommend the selection of a Circuit Breaker (FI switch)
suitable for these requirements.
When using a Circuit Breaker (FI switch) for personal safety, the activating current for the Circuit Breaker
(FI switch) should conform to the safety standards and regulations of the specific country.
• The electrician must equip the generator with a mains cable in accordance with the applicable
regulations. Ensure the mains cable connection is absolutely correct.
• The electrician must ensure the induction unit can always be disconnected from the power supply by a
switch, in accordance with the applicable regulations.
• All the cables must be routed/protected and tension free.
• The coils and sensor cables must not rest on one another.
•
Please put the control knob in the 0 (OFF) position BEFORE connecting to the electrical supply.
To setup the unit for operation:
1. Ensure the control knobs are at the OFF-Position.
ON-Position
Any position where
the White Line is
not pointing at ‘0’.
OFF-Position
White Line is
pointing at ‘0’.
2. Remove all objects from the griddle plate or braising pan.
- MODUKB10000100 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN MODUKB1000065 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN MODUKB7000150 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN MODUKB7000100 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN MODUKB700065 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN MODUGR10000 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN MODUGR7000 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN