6 electrical installation – Garland MODUKB10000150 INDUCTION BUILT-IN MODULE-LINE GRIDDLE & BRAISING PAN User Manual

Page 21

Advertising
background image

Installation

RTCSmp Built-In Module-Line Griddle & Braising Pan


Part # 4532414 Rev 2 (1/15/14)

21

4.6 Electrical Installation

IMPORTANT

• Refer to the electrical specifications in chapter 3 Dimensions and Technical Specifications AND the

rating plate/instruction labels on the unit. Always refer to the rating plate/instruction labels on the
unit to verify the electrical data. The rating plate/label information overrides the information listed in this
manual.

• Check and ensure the supply voltage and the line current match the specifications given on the rating

plate. A stable mains supply must be provided.

CAUTION

Wrong voltage will damage the induction unit. Follow
strictly the specifications on the rating plate.

• The electrical connections must satisfy the national and local electrical codes.
• If using a Circuit Breaker (Fault circuit Interrupter—FI switch), when switching a generator to a three-

phase mains supply, make sure that it can temporarily dissipate generated power, caused by the
asymmetry, which could result in activation of a Circuit Breaker (FI switch).

When selecting the Circuit Breaker (FI switch), make sure a frequency range of approx. 20kHz can be
generated by the generator DC and AC. We recommend the selection of a Circuit Breaker (FI switch)
suitable for these requirements.

When using a Circuit Breaker (FI switch) for personal safety, the activating current for the Circuit Breaker
(FI switch) should conform to the safety standards and regulations of the specific country.

• The electrician must equip the generator with a mains cable in accordance with the applicable

regulations. Ensure the mains cable connection is absolutely correct.

• The electrician must ensure the induction unit can always be disconnected from the power supply by a

switch, in accordance with the applicable regulations.

• All the cables must be routed/protected and tension free.
• The coils and sensor cables must not rest on one another.

Please put the control knob in the 0 (OFF) position BEFORE connecting to the electrical supply.

To setup the unit for operation:

1. Ensure the control knobs are at the OFF-Position.

ON-Position

Any position where
the White Line is
not pointing at ‘0’.

OFF-Position

White Line is
pointing at ‘0’.

2. Remove all objects from the griddle plate or braising pan.

Advertising