Chapter 5

Digital IO

5-1

5.0 Introduction

Digital I/O for the SQS-142 software is handled by an inexpensive Omron CPM1/CPM2
PLC. It is not necessary, however, to use external I/O with the SQS-142 software.

There are several benefits to using an inexpensive external PLC for I/O. First, noisy
high voltage wiring can be placed near the control sources, rather than routed into the
controller’s equipment rack. Only a single serial cable runs from the PLC to the
controller. The PLC also provides electrical isolation for the process controller. And
finally, the PLC’s ladder logic programming provides fail-safe process protection and
allows I/O to be easily tailored to each end user’s installation.

The PLC runs a small ladder logic program that communicates with the SQS-142
software. The ladder logic program transfers relay and input states from the PLC I/O
connecting block to internal registers. The SQS-142 software reads/writes to those
registers though the PLC’s Comm port. If you need to perform logic functions on an I/O
event, such as AND, OR, or INVERT, it can be easily accommodated by the PLC’s
ladder logic program.

Contact Sigma Instruments for more information on programming your PLC.