40

tina60e1-a (2011-04)

High & Low Trip Point

Both a High Trip Point and a Low Trip Point are assigned to
each setpoint. If the pressure in the vacuum system is higher
than the defined High Trip Point threshold, the corresponding
LED (<SP1> or <SP2>) is lit and the corresponding relay is
closed. If the pressure in the vacuum system is lower than the
defined Low Trip Point threshold, the correspoinding LED
(<SP1> or <SP2>) is lit and the corresponding relay is closed.

Setpoint

High Trip Point

Time t

Off

On

Off

Off

On

Setpoint
Low Trip Point

Measurement signal

(Pressure p)

Hysteresis
(10% of threshold)

Threshold value

Hysteresis
(10% of threshold)

Threshold value

The setpoints can only be programmed via

• the diagnostic port (→ [3])
• the DeviceNet, Profibus and RS485 interface

(

→ [3], [4], [5]).