4 Electrical connection
4.2
Galvanic isolation
Inputs/outputs
Galvanically isolated from each other
Relay outputs
Yes
Logic outputs DC 0/15 V
Yes
Solid state relay outputs
Yes
Open-collector outputs
Outputs of different expansion slots
Analog outputs
Yes
Digital inputs DC 0/24 V
Inputs of different modules (motherboard, expansion slots)
Analog inputs
Yes
Open-collector outputs
»
Analog inputs
Digital inputs
DC 0/24 V
Solid-state relay outputs
»
800 V (peak)
System bus
Logic outputs
DC 0/15 V
»
»
AC 30 V
DC 50 V
Voltage supply
DC 24 V
Relay outputs
»
AC 3800 V
Analog outputs
»
AC 30 V
DC 50 V
AC 30 V
DC 50 V
AC 30 V
DC 50 V
AC 30 V
DC 50 V
Voltage supply Out
Side system bus In
Side system bus Out
Voltage supply In
TIP!