Control technology | PROFIBUS communication manual

Commissioning of PROFIBUS

Detailed commissioning steps

3. Assign for each address of the input and output objects (e.g. %IB0, %QB0, ...) a

symbolic name which is non-ambiguous in the entire control configuration in

accordance with the IEC 61131 syntax (no blanks and leading digits in the variable

name):
• Symbolic names can be entered by a mouse-click in front of ’AT %... ;’.

The <F2> function key serves to open the input assistance in the »PLC Designer«.

Note!

When symbolic names are entered, corresponding system variables are created

for the PLC program.
Always use the system variables within the PLC program in order to access the

input and output objects or assign values to them.