Function library lenzedrive.lib, General signal processing, 1 enable of the fixed setpoints – Lenze DDS Function library Drive User Manual

Page 13

Advertising
background image

Function library LenzeDrive.lib

General signal processing

2.1.1

Programming fixed setpoints (L_FIXSET)

2−3

L

LenzeDrive.lib EN 1.7

2.1.1.1

Enable of the fixed setpoints

Number of required fixed setpoints

Number of the inputs to be assigned

1

at least 1

1 ... 3

at least 2

4 ... 7

at least 3

8 ... 15

4

Decoding table of the binary input signals:

Output signal
nOut_a =

1st input

bIn1_b

2nd input

bIn2_b

3rd input

bIn3_b

4th input

bIn4_b

nAin_a

0

0

0

0

anSollW1

1

0

0

0

anSollW2

0

1

0

0

anSollW3

1

1

0

0

anSollW4

0

0

1

0

anSollW5

1

0

1

0

anSollW6

0

1

1

0

anSollW7

1

1

1

0

anSollW8

0

0

0

1

anSollW9

1

0

0

1

anSollW10

0

1

0

1

anSollW11

1

1

0

1

anSollW12

0

0

1

1

anSollW13

1

0

1

1

anSollW14

0

1

1

1

anSollW15

1

1

1

1

0 = FALSE

1 = TRUE

Advertising