Function library lenzedrive.lib – Lenze DDS Function library Drive User Manual

Page 58

Advertising
background image

2.4.7

Integration (L_PHINTK)

Function library LenzeDrive.lib

Processing of phase−angle signals

2−48

L

LenzeDrive.lib EN 1.7

2.4.7.3

Calculation of the output signal

The output value at dnOut_p can be derived from the formula:

dnOut_p [inc]

+ nIn_v [rpm] @ t [s] @ 65536 [incńrev.]

(t = integration time, 16384

º 15000 rpm, 1 incr. = 1)

Example:

You want to determine the count of the integrator with a certain speed at the input and a certain
integration time t.

·

Given values:
– nIn_v = 1000 rpm

» (INT)1092

– t = 10 s
– Start value of the integrator is 0.

·

Solution:
– Conversion of the input signal at nIn_v:

1000 rpm

+ 1000 rev.

60 s

– Calculation of the output signal

dnOut_p

+ 1000 rev.

60 s

@ 10 s @ 65536 inc

rev.

+ 10922666 inc

Advertising