Function library lenzedrive.lib, Analog signal processing – Lenze DDS Function library Drive User Manual

Page 38

Advertising
background image

2.2.16

S−ramp generator (L_SRFG)

Function library LenzeDrive.lib

Analog signal processing

2−28

L

LenzeDrive.lib EN 1.7

Function

Load ramp generator

·

By using bLoad_b = TRUE loads the ramp generator with the signal at nSet_a.

·

This value is instantly accepted and output to nOut_a. No ramp−up or ramp−down through an
S−curve takes place.

·

As long as bLoad_b remains = TRUE, the ramp generator is disabled.

Acceleration and jerk

The maximum acceleration and the jerk can be adjusted separately.

n I n _ a

n O u t _ a

t

t

t

t

d w T i

d w T i

d w J e r k

R

Q

n D e l t a O u t _ a

Fig. 2−31

Line diagram

 Acceleration
‚ Jerk

·

Max. acceleration:
– By using dwTi you set the positive as well as the negative acceleration.
– The setting is calculated according to the formula:

1 s

@ 100 %
dwTi

·

Jerk:
– By using dwJerk you set up a jerk−free acceleration of the drive.
– The jerk is entered in [s] until the ramp generator operates with maximum acceleration (see

Fig. 2−31).

Advertising