Function library LenzeDrive.lib

Special functions

2.7.6

Right/Left/Quickstop (L_RLQ)

2−83

L

LenzeDrive.lib EN 1.7

2.7.6

Right/Left/Quickstop (L_RLQ)

This FB links the input for the direction of rotation and the QSP function, and is safe against an open
circuit.

bCw_b

L_RLQ

bQSP_b

bCwCCw_b

bCCw_b

Fig. 2−79

Right/Left/Quickstop (L_RLQ)

VariableName

DataType

SignalType

VariableType

Note

bCw_b

Bool

binary

VAR_INPUT

Right

bCCw_b

Bool

binary

VAR_INPUT

Left

bCwCCw_b

Bool

binary

VAR_OUTPUT

Status Right/Left

bQSP_b

Bool

binary

VAR_OUTPUT

Set Quickstop

Function

·

After mains connection and simultaneous TRUE at both inputs, the outputs are set as
follows:

Inputs

Outputs

bCw_b

bCCw_b

bCwCCw_b

bQSP_b

1

1

0

1

0 = FALSE

1 = TRUE

·

The following truth−table results only if the inputs were set to TRUE once after power
switch−on

Inputs

Outputs

bCw_b

bCCw_b

bCwCCw_b

bQSP_b

0

0

0

1

1

0

1

0

0

1

1

0

1

1

unchanged

unchanged

0 = FALSE

1 = TRUE

If you set both inputs to TRUE during operation, both outputs still have their previous output value.