Function library LenzeDrive.lib

Special functions

2.7.4

Speed preconditioning (L_NSET)

2−73

L

LenzeDrive.lib EN 1.7

2.7.4

Speed preconditioning (L_NSET)

This FB conditions the main speed setpoint as well as an additional setpoint (or other signals) for the
subsequent controller structure by using a ramp generator or fixed speeds.

L_NSET

nIEqOHysterisis

32767

*

+

-

/

x/(1-y)

1

0

1

1

0

1

anJogSetValue(1)

anJogSetValue(0)

anJogSetValue(14)

...

0

3

0

15

DMUX

adnTif(1)

adnTif(0)

adnTif(14)

...

adnTir(1)

adnTir(0)

adnTir(14)

...

dnTir

dnTif

0

3

0

15

DMUX

nCInhVal_a

bRfgStop_b

bRfg0_b

bNSetInv_b

nNSet_a

bJog2_b

bJog4_b

bJog8_b

bTI1_b

bTI2_b

bTI4_b

bTI8_b

nSet_a

bLoad_b

bNAddInv_b

nNAdd_a

ramp generator main setpoint

S-shape

main setpoint

nTiSShaped

x

y

byArithFunction

linking main

setpoint and

additional setpoint

nNOut_a

bRfgIEqO_b

CINH

dnTirAdd
dnTifAdd

JOG 0...15

TI 0...15

ramp generator additional setpoint

bJog1_b

1

bExternalCINH_b

bSShapeActive

Fig. 2−73

Speed preconditioning (L_NSET)

Variable name

Data type

Signal type

Variable type

Comment

nCInhVal_a

Integer

analog

VAR_INPUT

Here the signal is applied that the main setpoint
integrator is to accept when the controller is inhibited
(CINH).

bRfgStop_b

Bool

binary

VAR_INPUT

Holding (freezing) of the main setpoint integrator to its
current value.

bRfg0_b

Bool

binary

VAR_INPUT

Leads the main−setpoint integrator via the current
T

i

−times to 0.

bNSetInv_b

Bool

binary

VAR_INPUT

Control of the signal inversion for the main setpoint.

nNSet_a

Integer

analog

VAR_INPUT

Provided for main setpoint; other signals are
permissible.

bJog1_b

Bool

binary

VAR_INPUT

Selection and control of overriding "fixed setpoints"
for the main setpoint.

bJog2_b

Bool

binary

VAR_INPUT

bJog4_b

Bool

binary

VAR_INPUT

bJog8_b

Bool

binary

VAR_INPUT

bTI1_b

Bool

binary

VAR_INPUT

Selection and control of alternative "fixed setpoints"
for the main setpoint.

bTI2_b

Bool

binary

VAR_INPUT

bTI4_b

Bool

binary

VAR_INPUT

bTI8_b

Bool

binary

VAR_INPUT

nSet_a

Integer

analog

VAR_INPUT

Here the signal is applied that the main−setpoint
integrator is to accept when bLoad_b = TRUE.

bLoad_b

Bool

binary

VAR_INPUT

Control of the two ramp generators in special
situations, e.g. quick stop (QSP)

bAddInv_b

Bool

binary

VAR_INPUT

Control of the signal inversion for the additional
setpoint

Advertising