3 supported plc hardware, Supported plc hardware, Busserver s7 – Lenze Drive Server Bus server S7 getting started User Manual

Page 10

Advertising
background image

Busserver S7

L

71

Busserver S7 DE/EN 1.0

2.3

Supported PLC hardware

The following PLC hardware is supported: Siemens S7-300 and S7-400

For S7-400, the controllers must be connected to the PROFIBUS of the CPU.

For S7-300, the controllers can also be connected to PROFIBUS CP.

If an Ethernet connection is to be established between PC and PLC, the PLC must be equipped

with an Ethernet CP (e. g. CP343-1, CP443-1).

If a PROFIBUS connection is to be established between PC and PLC, the PLC must be equipped

with a PROFIBUS CP (e. g. CP343-5, CP443-5).

Required PLC data blocks/ RAM requirements

Two data blocks are required for data exchange with the drives. In addition, one function block instance

is to be activated for each drive to be addressed. This means that one data block per drive (instance

DB) is required for data management.
The RAM requirements of the PLC can be obtained from the following table:

Function block type

RAM requirements

Number of function blocks

required

Data exchange DB

508 bytes

2

Instance DB

150 bytes

Number of drives

Note!

The number of PLCs which can be simultaneously addressed depends on the interface module of the

PC or PLC.

The Siemens PC adapter supports only 4 communication links. Therefore, only 4 PLCs can be

addressed simultaneously.

For more information, please read the documentation on the interface module provided by the

manufacturer.