6.3.3

FC90 (FC Parameter)

Function for parameter data jobs from the PLC.

Parameters

Data type

Possible values/meaning

DrivePar_DB

IN: BLOCK_DB

Data block containing the parameter data

e.g.

DB80

Count

IN: INT

0...31 Memory location within DrivePar_DB

PB_Address

IN: BYTE

PROFIBUS address of the drive (hexadecimal)

Address 1 = 1, address 15 = F

R_W

IN: BOOL

TRUE Read drive

R_W

IN: BOOL

FALSE Write drive

Code

IN: WORD

Lenze code (hexadecimal):

W#16#XX

SubCode

IN: BYTE

Lenze sub-code (hexadecimal):

jB#16#XX

W_Value

IN: DINT

Value to be transmitted (FIX32)

Status

OUT: BYTE

Status of the function:

Status

OUT: BYTE

0x00 No errors
0x40 Count outside the range 0 ... 31
0x80 Controller error

For details see R_Value

0x81 When calling FB90, data for DriveServer_DB or

DrivePar_DB are invalid (identifier missing or incorrect).

Use the blocks supplied with the DriveServer library.

0x82 PB_Address incorrect (permissible values: 1 ... 123)
0x83 I/O error

For details see R_Value

0x84 Job could not be processed within the time set under

TimeOut.