Busserver S7

L

116

Busserver S7 DE/EN 1.0

6.6

Example project S7-300 with PROFIBUS-CP

The example project ”LenzeDriveServer” described in this chapter can be found in the sub-directory

\S7 of the DriveServer installation.

6.6.1

Hardware configuration

An S7-300 station is used as PLC.

CPU 315-2 DP, CP 342-5 and power supply PS 307 10A are configured in a RACK 300.

A PROFIBUS-DP sub-network with master system No. 1 (connected to the CPU) and another

sub-network with master system No. 180 (connected to the CP) are available. The drive

controllers are connected to the second master system.

Lenze fieldbus modules of type 2133 and 2131 are used as DP slave. These fieldbus modules

can be used for 8200 and 9300 drive controllers.

PROFIBUS addresses: 4 and 5 (hexadecimal)

Consistent communication with 8-byte parameter data and 4 process data words

(Configuration ”PAR(Kons.)+PZD(4Worte)”)

The following figure shows the hardware configuration in the Hardware Manager: