6 manual addition of drives, 7 drive parameters, Manual addition of drives – Lenze Drive Server Bus server S7 getting started User Manual

Page 19: Drive parameters, Busserver s7

Advertising
background image

Busserver S7

L

80

Busserver S7 DE/EN 1.0

4.2.6

Manual addition of drives

As an alternative to using the scan function, you can add the drives manually to the configuration.
1. Select the PLC to which you want to add a device from the tree structure.
2. Click

Add device.

3. Use the

Name input field to enter a name for the device and confirm with OK.

The name of the new device may only contain letters. It must not contain any special

characters.

The device will be added with the entered name as a configuration entry to the tree structure, and you

can now configure its parameters in the text fields on the right.

4.2.7

Drive parameters

Parameter name

Meaning

DP Address of the Device

PROFIBUS address

Timeout

Maximum time in [s] the bus server will wait for the processing of a
parameter command.

When the parameter sets are transferred, many commands are
simultaneously transmitted. Depending on the cycle time of the CPU,

waiting times between 20 - 30 s may therefore occur.

If problems occur during parameter set transfer, try a higher timeout
setting first.