Busserver S7

L

114

Busserver S7 DE/EN 1.0

6.5.7

Reading a parameter

FC4, network 3

UN

“TriggerRead”

= “TriggerRead”
CALL

FC 90

//data types

DrivePar_DB

:=”S7-Parameter”

//DB81

Count

:=0

//decimal: 0-31

PB_Address

:=”PB-Address”

//B#16#9

R_W

:=TRUE

//FALSE or TRUE

Code

:=”Code”

//W#16#C, code 12

SubCode

:=”Subcode”

//B#16#0, Sub-code 0

W_Value

:=”Value”

//DINT oder

L#xxx

Status

:=”ReadStatus”

//OUT, BYTE, status byte

R_Value

:=”ReadValue”

//OUT, DINT, value

Trigger

:=”TriggerRead”

//INOUT, BOOL

The variable TriggerRead is always set to TRUE.

Once a parameter read request has been processed correctly, TriggerRead is automatically

reset to FALSE.

FC90 and parameter R_W = TRUE are called to transmit a read request for a drive parameter.

Data exchange with

FB DRIVE (FB90) takes place via the data block S7-Parameter (DB81).

Input parameters are the request number, PROFIBUS address, write/read request and the code

and sub-code to be read.

Output parameters are the read value and the status byte.

Set parameter R_W to FALSE to transmit a write request for a drive parameter.

Tip!

Detailed information about the parameters of

FC90 can be found in chapter 6.3.3.

(

^ 102)