background image

Busserver S7

L

112

Busserver S7 DE/EN 1.0

6.5.4

OB1/ FC4

With

OB1, only the function FC4 is called, in which all other blocks are called.

6.5.5

Process data transfer

FC4, network 1

The following call is used to transmit two process data words (2PZD).

•

Process data word 1 is always the DRIVECOM control word.

•

Process data word 2 can be freely selected.

CALL FC 92

//FC92, 2 PZD

EA_Address

:=1008

//I-address, decimal

Enable

:=”Enable”

//BOOL

QSP

:=”QSP”

//BOOL

Reset

:=”Reset”

//BOOL

Setpoint1

:=”Setpoint1”

//INT, decimal

ControlWord

:=”ControlWord”

//WORD, control word

RDY

:=”RDY”

//OUT, BOOL

TRIP

:=”TRIP”

//OUT, BOOL

ActualValue1

:=”ActualValue1” //OUT, INT

StatusWord

:=”StatusWord”

//OUT, status word

•

The start address for the process data channel can be obtained from the hardware

configuration. (here: 1008)

•

The inputs Enable, QSP and Reset are set to enable the controller:

–

Enable = TRUE

–

QSP = FALSE

–

Reset = FALSE

•

The second process data word is assigned to the setpoint input.

•

Control word and status word conform to the DRIVECOM specification.

•

The DRIVECOM status machine has already been implemented in

FC92.

•

The outputs RDY and TRIP provide information about the controller status.

•

ActualValue1 is the value read out.

Tip!

Detailed information about the parameters of

FC92 can be found in chapter 6.3.5.

(

^ 105)

Use function block

FC91 to transmit three process data words.

(

^ 104)