Busserver S7

L

82

Busserver S7 DE/EN 1.0

Tip!

Proceed as follows to identify the sub-network ID in the STEP 7 program:
1. Start the ”NetPro” service program, e. g. by double-clicking a network in the SIMATIC manager

or clicking ”Connections” when the CPU is focussed.

2. Right-click the network connecting the controls with each other and select the

Object

Properties command from the context menu.

3. Enter the sub-network ID indicated in the

Object Properties dialog box in the Lenze S7

configuration tool.

The below figure shows an example of a possible configuration:

Tip!

If controllers are connected to the PROFIBUS of the master PLC and the PROFIBUS of the sub-system,

two PLCs must be configured in the Lenze S7 configuration tool.

In this case, the master PLC data are identical for both configuration entries.

For the sub-system PLC, you also have to enter the sub-system data as described above.