Safety option 30 – Lenze SO30 8400 protec User Manual

Page 38

Advertising
background image

Safety option 30

Operating mode
Safe inputs

5

l

38

EDS84DPSO01 EN 2.1

A

B

C

D



SSP94SM358_1

Fig. 5−3

Contact function test − error−free input signals

A

B

C

D

AIE

‚

ƒ

„



SSP94SM358_2

Fig. 5−4

Contact function test − faulty input signals

A, B

Safe input, channel A and channel B

C

Internal valuation of the safe input

D

Discrepancy monitoring

AIE

Fault acknowledgement



Discrepancy monitoring active

‚

Discrepancy monitoring − time−out

ƒ

Fault acknowledgement impermissible

„

Fault acknowledgement permissible

Advertising
This manual is related to the following products: