Safety option 30, Danger – Lenze SO30 8400 protec User Manual

Page 42

Advertising
background image

Safety option 30

Electrical installation

5

l

42

EDS84DPSO01 EN 2.1

Terminal assignment

}

Danger!

Danger to life through improper installation
Improper installation of the safety engineering systems can cause
anuncontrolled starting action of the drives.
Possible consequences:

ƒ

Death or severe injuries

Protective measures:

ƒ

The installation of the cables between X62, X63, and X64 and the connected
components must be shielded:
– Attach the shield at least in the connector shell.
– Also attach the shield to the connected component if possible.

X62 − connection of safety engineering system "Safety Option 30"

Pin

Connection

Description

Data

M12, 5−pole sockets, A−coded

84DPSO05_5

1

AIE

Error acknowledgement

2

24_ACK

24−V supply voltage for reset button

max. 300 mA

3

AIS

Restart acknowledgement

4

GND_SM

GND potential

5

GND_SM

Advertising
This manual is related to the following products: