6 safety functions, 1 safe torque off, Safety functions – Lenze SO30 8400 protec User Manual

Page 45: Safe torque off, Safety option 30, Danger

Advertising
background image

Safety option 30

Safety functions

Safe torque off

5

l

45

EDS84DPSO01 EN 2.1

5.6

Safety functions

5.6.1

Safe torque off

Safe Torque Off/STO

This function corresponds to a "Stop 0" according to EN 60204.

When this function is used, the power supply of the motor is immediately (t1) safely
interrupted. The motor cannot create a torque and thus no dangerous movements of the
drive can occur. Additional measures, e.g. mechanical brakes are needed against
movements caused by external force.

t

t

n

0

0

1

2

t1

I

STO

t1

t

0

I

0

SM301DIA_STO

0 Input signal of the request of a safety function

I

ON state

O OFF state

1 Speed characteristic n of the motor

t

Time axis

tx Action instant

2 Feedback(s)

The restart behaviour can be set (C15300/1). Function sequence and error response have
no adjustable parameters.

}

Danger!

If the request for the safety function is cancelled, the drive will restart
automatically.
You must provide external measures which ensure that the drive only restarts
after a confirmation (EN 60204).