3 emergency stop, Emergency stop, Safety option 30 – Lenze SO30 8400 protec User Manual

Page 49

Advertising
background image

Safety option 30

Safety functions

Emergency stop

5

l

49

EDS84DPSO01 EN 2.1

5.6.3

Emergency stop

Safe Stop Emergency/SSE

The emergency stop function activates STO or SS1. The function to be executed can be
adjusted (C15205). In special operation, the emergency stop cannot be avoided.

)

Note!

Connect the emergency stop buttons which must not be overruled by a special
operation to the emergency stop function. For this purpose, parameterise the
safe input as "emergency stop" (C15031).
The emergency stop function can also be requested with SSE bit via the safety
bus.

The activation of the function is reported internally to the standard device and via the
safety bus of the higher−level control.

Activation

How to activate the function:

ƒ

"OFF state" at a safe input, the function of which has been assigned by parameter
setting.

ƒ

Via a safety bus data telegram with corresponding content.