Technical data

5

l

40

EDS84DPSO01 EN 2.1

5.3

Technical data

24 V supply

The safety option 30 component does not require an external supply voltage.

Inputs and outputs

The inputs are isolated and designed for a low−voltage supply of 24 V DC.

Detailed features of the safe inputs

Terminal

Specification

[Unit]

min.

typ.

max.

I1A, I1B
I2A, I2B
AIE, AIS

PLC input, IEC−61131−2, 24 V, type 1

Low signal input voltage

V

−3

0

5

Input current at low signal

mA

15

High signal input voltage

V

15

24

30

Input current at high signal

mA

2

15

Input capacitance

nF

3.5

Repetition rate of the test pulses

ms

50

AIE, AIS

Input delay (operating time)

s

0.3

10

24I

Voltage supply only for AIE and AIS

V

24

CLA, CLB

PLC output, IEC−61131−2, 24 V DC, 50 mA

Low signal output voltage

V

0

0.8

High signal output voltage

V

17

24

29

Output current

mA

60

Cable capacity

nF

100

Cable resistance of a passive sensor

W

200

Safety option 30 does not provide any safe outputs.