Safety option 30

Electrical installation

5

l

43

EDS84DPSO01 EN 2.1

X63 − connection of the "Safety Option 30" safety engineering system

Pin

Connection

Description

Data

M12, sockets 8−pole, A−coded

84DSO05_8

1

CLA

Clock output, channel A

2

CLB

Clock output, channel B

3

GND_CLK

GND potential − clock output, channel A

4

I1A

Safe input 1, channel A

5

GND_I1

GND potential − input 1, channel A

6

I1B

Safe input 1, channel B

7

GND_CLK

GND potential − clock output, channel B

8

GND_I1

GND potential − input 1, channel B

X64 − connection of the "Safety Option 30" safety engineering system

Pin

Connection

Description

Data

M12, sockets 8−pole, A−coded

84DSO05_8

1

CLA

Clock output, channel A

2

CLB

Clock output, channel B

3

GND_CLK

GND potential − clock output, channel A

4

I2A

Safe input 2, channel A

5

GND_I2

GND potential − input 2, channel A

6

I2B

Safe input 2, channel B

7

GND_CLK

GND potential − clock output, channel B

8

GND_I2

GND potential − input 2, channel B