Safety option 30, Error management module error messages – Lenze SO30 8400 protec User Manual

Page 60

Advertising
background image

Safety option 30

Error management
Module error messages

5

l

60

EDS84DPSO01 EN 2.1

Error type/response/
Note

Description

Range

Error type/response/
Note

Description

Error number

Test functions − inputs

144

0x90

Stuck at High SD−In1, channel A
(Short circuit (High)

Trouble/−
SD−In1: OFF state

145

0x91

Stuck at High SD−In1, channel B

146

0x92

Stuck at High SD−In2, channel A

Trouble/−
SD−In2: OFF state

147

0x93

Stuck at High SD−In2, channel B

154

0x9A

CLA/CLB short circuit
Short circuit between the CLA and CLB clock outputs

Trouble/−
SD−In: OFF state

Safe parameterisation

160

0xA0

New parameter set deleted
(by the safe parameter setting in the Engineer)

−/−
Logbook entry: Info

161

0xA1

New safe parameter set loaded
(by the safe parameter setting in the Engineer or the procedure
with the module switch)

162

0xA2

Memory module parameter set − access error
(Error while accessing the parameter set of the memory module.)

Trouble/STO
OFF state for all SD−In

163

0xA3

Different parameter sets
(within the memory module and the drive−based safety)

164

0xA4

No safe parameter set in the drive−based safety
(drive−based safety does not have a parameter set)

165

0xA5

Defective SM301 parameter set
(parameter set of the drive−based safety is defective)

166

0xA6

Parameter set in memory module − format error
(Format error in parameter set of memory module)

167

0xA7

Parameter set − plausibility error

168

0xA8

Parameter set − communication error
(Communication error when loading the parameter set)

169

0xA9

Module ID does not equal effective safety address
(Module ID in the parameter set does not equal the effective
safety address)

Warning/STO
OFF state for all SD−In

Test functions − internal module

192

0xC0

Reference voltage error

Trouble/STO
OFF state for all SD−In

193

0xC1

6 V voltage error

194

0xC2

5 V voltage error

195

0xC3

2.6 V voltage error

Tab. 5−2