2 status display, Status display, Safety option 30 – Lenze SO30 8400 protec User Manual

Page 39

Advertising
background image

Safety option 30

Status display

5

l

39

EDS84DPSO01 EN 2.1

5.2

Status display

Light−emitting diodes (LED) on the front of the controller display the operating status of
the safety engineering system.

E84DPSO06 SO30

Pos.

Colour

State

Description

S−State

green

on

Communication between standard device and safety system
is running

blinking

Drive−based safety is in service status

off

Communication between standard device and safety system
is not possible

S−Error

red

on

Fault, trouble or warning

blinking

Drive−based safety is not accepted by the standard device

off

Error−free operation

S−Acknw

yellow

on

A parameter set acceptance must be acknowledged

S−Enable

yellow

on

Controller is enabled

blinking

Safety function is active (non−safe display)

Advertising
This manual is related to the following products: