MacDon A40-D Pull-Type User Manual

Page 136

Advertising
background image

SECTION 7 MAINTENANCE AND SERVICING

169000

134

Revision F

g. If timing is off, proceed as follows:

1. Loosen right side timing belt sufficiently to

allow skipping the belt one or more teeth as
required. Refer to Section 7.8.9.4 Adjusting
Tension: RH Knife Drive Timing Belt –

A30-D, or 7.8.10.4 Adjusting Tension: RH
Knife Drive Belt – A40-D.

2. If RIGHT KNIFE leads LEFT KNIFE, rotate

RIGHT HAND driven pulley (C) clockwise.

3. If RIGHT KNIFE lags LEFT KNIFE, rotate

RIGHT HAND driven pulley (C)
counterclockwise.

4. Tighten right side timing belt. Refer to

Section 7.8.9.4 Adjusting Tension: RH Knife
Drive Timing Belt – A30-D, or 7.8.10.4
Adjusting Tension: RH Knife Drive

Belt – A40-D.

C