Installation, Zero clearance kit installation – Regency Energy E18 Small Gas Insert User Manual

Page 13

Advertising
background image

Regency

®

E18 Gas Fireplace Insert

13

INSTALLATION

35-9/16"

(903mm)

41"

(1042mm)

14-1/2" (369mm)

36"

(914mm)

32-1/2" (825mm)

37-13/16"

(961mm)

1. Shut down existing unit and allow to cool to room temperature.

2. Turn off gas supply and disconnect electrical.

3. Remove all accessories from existing unit, ie. glass doors, louvers, etc.

4. Remove any tiles, hearth or surround from existing unit (if required).

5. Disconnect gas supply from existing unit.

6. Cut away a perimeter of drywall around the existing unit to expose the

framing. See example below.

7. Uninstall existing unit from framing.

8. Disconnect venting from existing unit - remove carefully to avoid damage.

9. Remove existing unit from framed opening.

10. Measure framed opening and compare to dimension requirements

for ZC kit (noted below).

Remove existing wood header and replace with supplied steel

stud. Supplied stud will be longer than framed opening, adjust to fi t
before installing.

Additional adjustments to framed opening may be required.

11. Bend ZC kit side pieces as shown and remove knockouts (if required)

before installation.

Bend to 90º
secure in place to
supplied steel stud

Remove knockouts
(if required)

Bend to 90º

616-900 E18 ZC Kit contains the following:

1

ZC Left Section

1

ZC Right Section

1

ZC Base Section

1

ZC Back Center Section

1

ZC Trim surround LH

1

ZC Trim surround RH

1

ZC Trim surround Top

1

ZC Lower Trim piece

1

Steel Stud header (required)

26

(904-897) #8 x 9/16" black wafer screws

25

(904-576) #8 x 1/4" Phillips screws

NOTE: Before removing existing unit - ensure ZC kit will fi t.

Framed opening - Top View

Framed opening - Side View

Cut drywall

Remove unit from framing

Side pieces

ZERO CLEARANCE KIT INSTALLATION