Installation, E18 installation specifications – Regency Energy E18 Small Gas Insert User Manual

Page 20

Advertising
background image

20

Regency

®

E18 Gas Fireplace Insert

INSTALLATION

E18 INSTALLATION SPECIFICATIONS

See Installation of E18 into Existing Units for General Installation Guidance - for vent connection confi guration.

This install of the E18 uses

Vent Connection Type A

.

The length of 4" Flex needed is 4 -1/8" semi-expanded.

Secure fl ue adapter top plate to under side of existing fi rebox using 4 self tapping screws.

The height of the unit installed is shown below.

 

PP



 

PP



 

PP



$

(3)LUHER[

/HJ

Right side shown

 

PP



 

PP



%

(3)LUHER[

(,QVHUW

'(7$,/%

6&$/(

$GDSWRU3ODWH

IDVWHQHUVHWWLQJ

)OH[$GDSWRU/HQJWK

&ROODU3ODWH6HWWLQJ9HQWSRVLWLRQ

1. Loosen 2 x Phillips screws on both right and left legs.

2. See above diagram below for required leg setting.

3 Install with supplied Phillips screws to pre-punched holes and tighten previous screws that were loosened in Step 1.

4. Keep left side leg loose until outer fi rebox is in position in ZC box - to allow adjustment of gas line.

EP28-4 / EP28-5 INSTALLATION SPECIFICATIONS

Set to this

hole

Set to this

hole

Secure top plate to fi rebox w/4 screws.

Secure vent slide plate to fl ex pipe with 4

screws

Advertising