INSTALLATION

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS

FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

CONVERSION KIT 616-969 - NATURAL GAS TO PROPANE

1. Turn the unit off and allow it to cool to room

temperature.

2. Unplug or disconnect power source to unit.

3. Remove glass front (see manual).

4. Remove Log or Glass Burner. (see manual)

5. Unscrew NG burner orifi ce and replace with

LP orifi ce.

.

7. Turn control knob to the “OFF” position

15. Pull off the pilot cap to expose the pilot orifi ce.

16. Unscrew the pilot orifi ce with the allen key and

replace with the LP pilot orifi ce in the kit.

8. Remove the black protection

cap by hand from the hi-low
knob (Fig.1).

11. Flip the screw (Fig. 3).

12. Using the Allen wrench as

shown in Fig.4, rotate the
screw clockwise until snug,
do not overtighten.

9. Insert a 5/32” or 4mm Allen

wrench into the hexagonal
key-way of the screw (Fig. 2),
rotate it counter-clockwise
until it is free and extract it.

10. Check that the screw is clean and if necessary

remove dirt.

WARNING!

Do not over tighten the screw.

Recommended to

grip the wrench by the short side.

13. Verify that if the conversion is from NG to LPG,

the screw must be re-assembled with the red
o-ring visible (Fig. 5).

14. Re-assemble the black protection cap

(Fig. 6).

Burner Orifi ce

Fig. 1

Fig.2

Fig.3

Fig.4

LPG Configuration

Red o-ring visible

Fig.5

Fig. 6

LP conversion Kit 616-969

1

904-037

LP orifi ce injector #35

1

904-977

orifi ce #55

1

908-528

Propane Label Red

1

918-590

Converted to LPG label

1

904-529

Allen Key

1

919-191

Instruction Sheet

17.

Attach the label “This unit has been converted

to LPG” near or on top of the serial # decal.

18.

Replace yellow “NG” label with red “LPG” label.

19.

Reverse steps 3 - 1.

20.

Check for gas leaks.

21.

Check inlet and outlet pressures.

22.

Check operation of fl ame control.

23. Adjust the burner aeration setting to Fully Open

and adjust as required for the best fl ame picture.

24.

See manual for Gas Pressure Testing instruc-

tions.

This conversion kit shall be installed by a qualifi ed

service agency in accordance with the manufac-

turer's instructions and all applicable codes and

requirements of the authority having jurisdiction. If

the information in these instructions is not followed

exactly, a fi re, explosion, or production of carbon

monoxide may result causing property damage,

personal injury, or loss of life. The qualifi ed service

agency is responsible for the proper installation of

this kit. The installation is not proper and complete

until the operation of the converted appliance

is checked as specifi ed in the manufacturer's

instructions supplied with the kit.