Maintenance, Valve replacement installing valve – Regency Energy E18 Small Gas Insert User Manual

Page 58

Advertising
background image

58

Regency

®

E18 Gas Fireplace Insert

MAINTENANCE

1. Shut off the gas and electrical supply.

2. Remove Faceplate Control Cover (see instructions in manual).

3. Remove Glass Door (see instructions in manual).

4. Remove Log Set and Embers or crystals and stones (if installed).

5. Remove Burner and Panels (see instructions in this manual).

6. Unplug the TH and TN/TP wires on the front of the Valve.

VALVE REPLACEMENT

INSTALLING VALVE

7. Disconnect piezo wire from piezo ignitor.

8. Unscrew the 8 screws holding down the Valve Tray.

9. Slide the Valve Tray out about half way giving easier access to the gas

connection at the valve.

1. Place new valve tray and gasket into position.

2. Reverse Steps 10-1.

3. Check for gas leaks.

10. Disconect the gas line and remove the valve tray.

Diagram 17.1

Diagram 17.2

Diagram 17.3