STEP #4: SURROUND INSTALLATION

1. Remove glass door from unit (see instructions in manual).

2. Remove control box from rear surround by removing 2 screws.

Disassemble control box, insert switches; reassemble.

3. Remove left mounting bracket by removing 3 screws.

Control Box

Rear surround

4. Run wire from unit through notch in mounting bracket and then

to control box as shown below.

5. Attach control box to left mounting bracket with 2 screws - reat-

tach mounting bracket.

6. Tuck wire harness on left top groove and secure with wire clips.

7. Feed power cord through left grommet. (If power outlet is on

the right side of the unit, feed power cord through right grom-
met and use wire clips to secure power cord inside the unit).

8. Secure backing plate with mounting brackets to outer box by

screwing 4 self tapping screws on fl anges.

10. Reinstall glass door (see instructions in manual).

11.

Install control cover, adjust horizontal alignment by sliding
control cover to ensure even spacing on both sides. Ensure

control cover is seated down all the way.

9. Attach front faceplate with 4 screws (2 on each mounting

bracket). (Touch up screws with provided black paint, after
install.)

Notch in

mounting

bracket

Diagram 10.5

Diagram 10.6

Diagram 10.7

Diagram 10.8

Diagram 10.9

Diagram 10.10

ONLY TRIM KIT SUPPLIED BY THE MANUFACTURER SHALL BE

USED IN THE INSTALLATION OF THIS APPLIANCE.

DRAFT RELIEF OPENINGS MUST NOT BE COVERED OR BLOCKED.