Safety label – Regency Energy E18 Small Gas Insert User Manual

Page 5

Advertising
background image

Regency

®

E18 Gas Fireplace Insert

5

SAFETY LABEL

This is a copy of the label that accompanies each Regency

®

Gas Insert. We have

printed a copy of the contents here for your review. The safety label is located on the
front inside base of the unit visible when the bottom louver is open.

Note: Regency

®

units are constantly being improved. Check the label on the

unit and if there is a difference, the label on the unit is the correct one.

Please note that with the addition of thermostat control and outside
combustion air supply, this unit is approved for bedroom installations.

For the State of Massachusetts, installation and repair must be done by a plumber
or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches
in length.

For the State of Massachusetts, the appliances individual manual shut-off must
be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm
in accordance with NFPA 720 and a CO alarm with battery back up in the same
room where the gas appliance is installed.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE

Serial No. / No de serie

4001172

415

415

Min. supply pressure

5"

WC

(1.25kPa)

Low Setting Man. pressure

1.6"

WC

(0.40kPa)

Max. Manifold pressure

3.5"

WC

(0.87kPa)

Orifice size

44

DMS

(2.64mm)

Minimum input

15,000 Btu/h

(4.40kW)

Altitude

0-4500ft

(0-610m)

Maximum input

21,600

Btu/h

(6.33kW)

919-179a

NATURAL GAS FIREPLACE INSERT: MODEL E18-NG

PROPANE FIREPLACE INSERT: MODEL E18-LP

12"

WC

(2.99 kPa)

6.4"

WC

(1.59 kPa)

10"

WC

(2.49 kPa)

55

DMS

(1.6mm)

17,000

Btu/h

(4.98kW)

0-4500ft

(0-610m)

20,500

Btu/h

(6.01kW)

FPI Fireplace Products International Ltd.Delta BC, CANADA

MADE IN CANADA / FABRIQUE AU CANADA

Model: E18-NG

Model: E18-LP

Factory Equipped For Altitude 0-4500ft. (0-

m)

1370

Duplicate Serial number

This appliance must be installed in accordance with local codes, if any; if none,
follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane
Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240
MH, Mobile Housing, in Canada, or with the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a
standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured
Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for
Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and
may be installed in an aftermarket, permanently located, manufactured (mobile)
home where not prohibited by local codes. See owner's manual for details.
WARNING. This fireplace has been converted for use with a gas fireplace insert
only and cannot be used for burning wood or solid fuels unless all original parts
have been replaced, and the fireplace re-approved by the authority having
jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels
règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code
ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou
CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280,
Manufactured Home Construction and Safety Standard. Si ces normes ne sont
pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A,
Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles.

AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz
encastrable et ne peut être utiliser pour brûler du bois ou d'autres combustibles
solides à moins que toutes les pièces d'origine aient été remplacées et que le
foyer ait été approuvé de nouveau par l'autorité compétente.

For use with glass doors certified with the appliance only

This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil peut être installé dans une maison préfabriquée ou
mobile (É.-U. seulement) installée à demeure si les règlements locaux le
permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet
appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de
conversion certifiée est fournie.

Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil

Minimum Clearances to Combustibles:

Min. Mantel Height A 17-7/8"(453mm)
Min. Ceiling

B 37-7/8"(961mm)

D

Side wall E 6" (152mm)
Max. Mantel Depth F 9" (229mm)

Height

37-1/2"(953mm)

Degagement Minimum Des Materiaux
Combustibles:

Listed:

Certified for/Certifi e pour:
Tested to:

CANADA and U.S.A.

VENTED GAS FIREPLACE HEATER

/ FOYER AU GAZ À ÉVACUATION

é

CAN/CGA-2.17-M91(R2009)

Electrical supply / Électrique 115VAC, 2.5 A, 60Hz,
Less than 10A Fan Part # 911-071

Min. supply pressure
Low Setting Man. pressure
Max. Manifold pressure
Orifice size
Minimum input
Altitude
Maximum input

Factory Equipped For Altitude 0-4500ft. (0-1370m)

F

D

E

B

A

VENTED GAS FIREPLACE HEATER -

NOT FOR USE WITH

SOLID FUELS. /

NE PAS

UTILISER AVEC DUCOMBUSTIBLE SOLIDE.

FOYER AU GAZ À ÉVACUATION -

Conforms to: ANSI Z21.88a-2012
Certified to: CSA 2.33a-2012