Installation, Safety switches, Operation controls fireplace controls – Regency Energy E18 Small Gas Insert User Manual

Page 54

Advertising
background image

54

Regency

®

E18 Gas Fireplace Insert

INSTALLATION

$FFHVV3DQHO

2Q2II6ZLWFK

)DQ6SHHG&RQWURO

)ODPH&RQWURO

SAFETY SWITCHES

The E18 uses two safety switches to maintain proper operation.

The fi rst is a Spill Switch which will shut off the appliance if continuous spilling of exhaust gas from the drafthood occurs. The spill switch will shut off the
Main Burner but not the Pilot. This switch is resets automatically, if the problem persists the appliance will cycle on and off. If this occurs. shut the unit off and
contact a technician.

The second is a Primary Limit Switch. This switch confi rms that the circulation fan is operating normally. If for any reason the circualtion fan fails, the Primary
Limit Switch will turn off the Main Burner but not the Pilot before the appliance becomes too hot. This switch is automatic resetting, so if the problem persists
you will see your appliance cycling on and off. If this occurs shut the unit off and contact a technician.

OPERATION CONTROLS

FIREPLACE CONTROLS

The E18 has 3 controls for controlling fl ame height, fan
speed and fl ame on/off. The fan on the E18 is designed
to come on once the fi replace has reached a pre-deter-
mined temperature, and to go off once the temperature
has dropper following use.


The speed of the fan can be varied by adjusting the Fan

Speed Control dial up or down. These controls are located
to the left side of the Surround Panels.

Providing that the pilot system is in standing mode, the

main burner can be turned on or off by way of a

switch located just below the Fan Speed Control dial.

See the Lighting Instruction section in this manual
for information on lighting the pilot.

The fl ame height can be adjusted from minimum to maxi-

mum by way of an adjustment knob on the Control Valve,
located behind the Access Panel.

The Access Panel is held in place by magnets and can

simply be lifted away from the unit and set aside.

Note: Supplied white cord channel

Use cord channel to obscure cord and keep tidy. The
cord is located on the left hand side of the appliance.

1. Open channel and feed cord through.

2. Peel off backing of cord channel and adhere to hearth.

Diagram 15.1

Advertising